EnglishEspañolPortuguese
Innovations in Process Instrumentation & Control.
Company Certified ISO-9001:2008
Inquiry List

Portable Flowmeters

 

PortaFlow

PORTABLE ULTRASONIC TRANSIT TIME + DOPPLER EFFECT FLOWMETER

With Anti-Bubble Algorithm. Can plot the velocity profile inside the pipe.

Accuracy (always) 1%. With data logger an battery that lasts longer than 12 Hrs.

Add this product to the Inquiry List.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
Ideal to measure dirty liquids or liquids with a high degree of aeration. This definition normally includes liquids with at least 75 ppm of solids or 75 ppm of gas bubbles. The minimum size of the solids or bubbles should be >= 100 uM.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
This flowmeter is based in a Doppler Effect Ultra-Sonic principle. Requires relatively dirty or aereated liquids. The particles or bubbles are the echo producers.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

F-FSD

NON-CONTACT SENSORS FOR PORTAFLOW FLOWMETER

Four sensor sizes to cover the range between 1/2" and 240"

Optionally for extreme temperatures..: -40 to +200 °C.

Add this product to the Inquiry List.
The sensing device or active parts of this instrument have direct no contact with the process fluid.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
Ideal to measure dirty liquids or liquids with a high degree of aeration. This definition normally includes liquids with at least 75 ppm of solids or 75 ppm of gas bubbles. The minimum size of the solids or bubbles should be >= 100 uM.
 

G-PT400

LOW COST ULTRASONIC TRANSIT TIME FLOWMETER

Can measure clean and non-aereated liquids in pipes from 1/2" to 80".

Includes data logger. Applicable with temperatures from -20 to +135 °C.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

G-PDFM5

DOPPLER EFFECT ULTRASONIC FLOWMETER

Ideal for waste water or similar liquids.

Can measure in pipes from 1/2" to 180" and with service temperatures from -40 to +120 °C

Add this product to the Inquiry List.
This instrument is suitable to measure all kind of waste water. Including raw or partially filtered sewage.
Ideal to measure dirty liquids or liquids with a high degree of aeration. This definition normally includes liquids with at least 75 ppm of solids or 75 ppm of gas bubbles. The minimum size of the solids or bubbles should be >= 100 uM.
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flowmeter is based in a Doppler Effect Ultra-Sonic principle. Requires relatively dirty or aereated liquids. The particles or bubbles are the echo producers.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Stringray

OPEN CHANNEL PORTABLE FLOWMETER

Works by integrating the Area-Velocity curve.

Measures from 0.03 to 3 m/sec, and depths up to 4.5 m. Includes data logger.

Add this product to the Inquiry List.
This instrument is suitable to measure all kind of waste water. Including raw or partially filtered sewage.
This flowmeter is based in a Doppler Effect Ultra-Sonic principle. Requires relatively dirty or aereated liquids. The particles or bubbles are the echo producers.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

K-244x

INDUSTRIAL THERMAL ANEMOMETER

Ideal for HVAC ducts. Works at high air temperatures.

Measures from 0 to 60 m/Sec, with temperatures up to -40 ... +200 °C.

Add this product to the Inquiry List.
This flowmeter is based in a thermal technology. Depending on the specific models can be by heating the fluid (laminar flow primary  body) or by thermal dispersion.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
 

VT-200

GENERAL PURPOSE THERMO-ANEMOMETER

Available with thermal or rotating vane probe.

Works in a range from 0.15 to 35 m/sec.

Add this product to the Inquiry List.
This flowmeter is based in a thermal technology. Depending on the specific models can be by heating the fluid (laminar flow primary  body) or by thermal dispersion.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

VT-Cone

INTEGRATING CONE FOR VENTILATION DUCTS

Suitable to measure with high accuracy air flow in ventilation diffusers.

Add this product to the Inquiry List.
 

Copyright &copy; 2012...2016 CONAR. Innovations in Process Instrumentation & Control.