EnglishEspañolPortuguese
Innovations in Process Instrumentation & Control.
Company Certified ISO-9001:2008
Inquiry List

ElectroMagnetic Flowmeters

 

EMG-F

STANDARD ELECTRO-MAGNETIC FLOWMETER

Available between 1/2" and 16". Service temperatures up to 200 °C.

Linings in PTFE or Ebonite. Hastelloy C standard electrodes.

Add this product to the Inquiry List.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

FloNet-F

ADVANCED ELECTROMAGNETIC FLOWMETER

Nominal sizes between 1/4" and 48". Conductivity as low as 5 uS/cm.

Wide selection of process connections and construction materials.

Add this product to the Inquiry List.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Instrument available with HART digital communications protocol over the 4...20 output signal. HART is a very convenient tool for the instrument remote re-calibration, re-configuration or diagnostics.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

EMG-L

ELECTROMAGNETIC FLOWMETER FOR LARGE PIPES

Available from 18" through 80". Ideal for drinking or waste water.

Add this product to the Inquiry List.
This instrument is suitable to measure river water, well water or other raw waters.
This instrument is suitable to measure all kind of waste water. Including raw or partially filtered sewage.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

EMG-W

WAFER STYLE ELECTRO-MAGNETIC FLOWMETER

Nominal sizes between 1" and 12". Lining in PTFE and Hastelloy C electrodes.

Simple and affordable solution.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

EMG-M

MINIATURE ELECTROMAGNETIC FLOWMETER

Special for low liquid flow. Nominal diameters between 3 and 20 mm.

Threaded or sanitary connections.

Add this product to the Inquiry List.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

FloNet-S

SANITARY ELECTROMAGNETIC FLOWMETER

With ISO Clamp (Tri-Clover) or sanitary couplings. Between 1/2" and 4".

Minimum conductivity: 20 uS/cm. Up to 10 bar and 150 °C.

Add this product to the Inquiry List.
This product is new and has been launched into the market or totally revamped less than one year ago.
Instrument available with Sanitary Process Connections. Depending on the requirements these connections could be: a) ISO-2852 (TriClover, 3A) Clamp, b) Danish Union according to DS-722, c) Swedish Union as per SMS-1145, or d) DIN Union as per DIN-11851.
Suitable for sanitary Clean in Place processes. This typically means service at T >= 80 °C and with fluids such as lean solutions of NaOH, HNO3, detergents and similar.
This instrument is suitable for sterile sanitary processes with "Sterilize in Place" procedures. This typically means service at T >= 120 °C for a minimum time of 30 minutes and in direct contact with steam or other chemicals.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This electro-magnetic flowmeter can be supplied with electrodes made of special materials (such as, Hastelloy C, Titanium, Tantalum, etc) or with special functions (self cleaning design)
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

EMG-I

INSERTION ELECTROMAGNETIC FLOWMETER

Suitable for very large pipes. Diameter range: 4" through 160".

Optionally with "hot tap" mounting under line pressure.

Add this product to the Inquiry List.
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
Insertion instrument suitable to be mounted in the process piping (with no service interruptions) by Hot Tap procedures.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
 

ATD-VN

ELECTROMAGNETIC FLOWSENSOR

Available in three sizes: 1/4", 1/2" and 1". Measurement flow ranges between 0.05 and 60 LPM.

Optionally with sanitary connections. Very low cost solution.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
This flowmeter works based in an electromagnetic induction technology. It is only suitable to measure electric conductive liquids, typically liquids containing water. The minimum electric conductivity should be in the range of 5...20 uSiemens.
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Copyright © 2012...2016 CONAR. Innovations in Process Instrumentation & Control.