EnglishEspañolPortuguese
Innovations in Process Instrumentation & Control.
Company Certified ISO-9001:2008
Inquiry List

Ultra-Sonic Flowmeters, Non-Contacting & In-Line

 

TimeDelta

TRANSIT TIME ULTRASONIC FLOWMETER. (Non-Contact)

Suitable for pipes ranging from 1/2" to 240". Accuracy up to 1% of reading.

Optionally with double beam system.

Add this product to the Inquiry List.
This instrument, equipment or option is among the most popular within its category.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Instrument available with ModBus-RTU digital communication protocol over a RS-485 interface.
Download the general catalog of this product line.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

DuoSonics

HYBRID ULTRASONIC FLOWMETER. (Non-Contact)

Combines Transit Time with Doppler Effect. For pipes from 11/2" to 40".

Optionally plots the velocity profile inside the pipeline. Accuracy to 0.5%.

Add this product to the Inquiry List.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
Ideal to measure dirty liquids or liquids with a high degree of aeration. This definition normally includes liquids with at least 75 ppm of solids or 75 ppm of gas bubbles. The minimum size of the solids or bubbles should be >= 100 uM.
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
This flowmeter is based in a Doppler Effect Ultra-Sonic principle. Requires relatively dirty or aereated liquids. The particles or bubbles are the echo producers.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Instrument available with ModBus-RTU digital communication protocol over a RS-485 interface.
Download the general catalog of this product line.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

MFlow-PW

ULTRASONIC FLOW TRANSMITTER. (Non-Contact)

Ideal to measure ultra-pure water or drinking water.

Covers a pipe diameter range from 1" to 24" with up to 1.5% of accuracy.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Download the general catalog of this product line.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

G-TTFM

TRANSIT TIME FLOW TRANSMITTER (Non Contact)

Affordable ultrasonic flowmeter. Suitable for clean liquids.

Can measure with pipes between 1/2" and 48". Three transmission modes: "V", "Z" and "W".

Add this product to the Inquiry List.
This product is new and has been launched into the market or totally revamped less than one year ago.
This product has one of the lowest total purchase prices, when compared with others within its category.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
This instrument is available with auxiliary alarm and/or control outputs. Typically these are SPDT contacts, free of potential, that can be configured for High and/or Low conditions.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

G-DFM5

DOPPLER EFFECT FLOW TRANSMITTER. (Non-Contact)

Suitable for pipes ranging from 1" to 180". Can measure waste water and raw sewage.

Accurate to 2% of reading.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
This instrument is suitable to measure all kind of waste water. Including raw or partially filtered sewage.
Ideal to measure dirty liquids or liquids with a high degree of aeration. This definition normally includes liquids with at least 75 ppm of solids or 75 ppm of gas bubbles. The minimum size of the solids or bubbles should be >= 100 uM.
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flowmeter is based in a Doppler Effect Ultra-Sonic principle. Requires relatively dirty or aereated liquids. The particles or bubbles are the echo producers.
Transmitter with independent circuits for the power supply (that typically can be 24 V, 110 V or 220 V) and the signal output, that normally is (0)4...20 mA, 0...5 VCD, 1...5VDC or 0...10 VDC.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
This instrument is available with auxiliary alarm and/or control outputs. Typically these are SPDT contacts, free of potential, that can be configured for High and/or Low conditions.
Download the general catalog of this product line.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Sonoelis

IN-LINE ULTRASONIC FLOW TRANSMITTER

One or two beam system. Accurate to 0.5% of reading.

For pipes ranging from 1" to 12". Can measure all liquids.

Add this product to the Inquiry List.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Instrument with transmission (or re-transmission) ouput signal in the range of 4 .... 20 mADC.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Flomic-G

BATTERY POWERED ULTRASONIC FLOWMETER

For pipes from 1" to 12". Ideal for water distribution networks.

Includes local data recording and/or transmission outputs.

Add this product to the Inquiry List.
Instrument or equipment available with Environmental (Ingress) Protection IP-68 (Equivalent to NEMA-6P). Allows full inmersion for indefinite time.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
This instrument get its electric power from a Lithium battery. The battery's life span can typically go from 3 to 10 years. Optionally, It may also have an external power supply.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Flomic-W

ULTRASONIC FLOWMETER FOR WATER DISTRIBUTION NETWORKS

Battery powered. Includes data-logger.

For pipes ranging from 1" to 8". Ideal for drinking water distribution.

Add this product to the Inquiry List.
This product has one of the lowest total purchase prices, when compared with others within its category.
Instrument or equipment available with Environmental (Ingress) Protection IP-68 (Equivalent to NEMA-6P). Allows full inmersion for indefinite time.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This flowmeter has no restriction to the fluid passage (Full bore section). It is therefore, a "zero" pressure drop instrument.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
This instrument get its electric power from a Lithium battery. The battery's life span can typically go from 3 to 10 years. Optionally, It may also have an external power supply.
Instrument available with integrated digital data logger. Typically the memory is non-volatile and the data is downloaded using a special software package through a USB, RS-232 or wireless infrared interface.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Flomic-I

INSERTION ULTRASONIC FLOWMETER

Single or dual beam system. Special for large pipes: 8" to 80".

Add this product to the Inquiry List.
Ideal to measure clean liquids with low degree of aeration. This definition typically involves liquids with Turbidity <= 10 g/l and Gas Concentrations <= 3% per volume. (Note: Gas in Liquid will generate a positive error in volumetric flowmeters).
This instrument is convenient, both from an economic and technical point of view, to measure in large pipes. Typically nominal sizes larger than 10". Consult the catalog or data-sheet in order to determine the maximum size available.
This flow flowmeter is based in the Ultra-Sonic Transit Time (Time of Flight) principle. It is a high reliability technology. Suitable for relatively clean and low aereated liquids.
Insertion instrument suitable to be mounted in the process piping (with no service interruptions) by Hot Tap procedures.
Instrument with transmission (or re-transmission) ouput signal in the range of 4 .... 20 mADC.
This instrument is available with direct digital pulse output. These puses typically can be used for volume or mass totalization.
Download the technical Data Sheet of this product.
Download an Instruction Manual (Installation anr/or operation and/or maintenance) of this product.
 

Copyright &copy; 2012...2016 CONAR. Innovations in Process Instrumentation & Control.